BH GSO IEC/TR 61852:2016

Bahraini Standard   Current Edition
· Approved on 08 February 2016 ·

Medical electrical equipment - Digital imaging and communications in medicine (DICOM) - Radiotherapy objects

BH GSO IEC/TR 61852:2016 Files

English null Pages
Current Edition Reference Language

BH GSO IEC/TR 61852:2016 Scope

This report specifies the following information objects: 1) A DICOM Image Information Object for Radiotherapy. It specifies the semantic content of RT Images. It is commonly abbreviated to the RT Image IOD. It also includes the corresponding Storage SOP Class so that this IOD can be used in Network and Media Storage exchanges. The scope of the RT Image IOD is radiotherapy images which have been obtained on a conic imaging geometry, such as that found on conventional simulators and portal imaging devices. It can also be used for calculated images using the same geometry, such as digitally reconstructed radiographs (DRRs). 2) A DICOM Dose Information Object for Radiotherapy. It specifies the semantic content of RT Doses. It is commonly abbreviated to the RT Dose IOD. It also includes the corresponding Storage SOP Class so that this IOD can be used in Network and Media Storage exchanges. The scope of the RT Dose IOD is radiotherapy dose distributions which have been calculated on a radiotherapy treatment planning system, represented as two- or threedimensional dose grids, groups of named or unnamed dose points, isodose curves, and dose-volume histograms (DVHs). 3) A DICOM Structure Set Information Object for Radiotherapy. It specifies the semantic content of RT Structure Sets. It is commonly abbreviated to the RT Structure Set IOD. It also includes the corresponding Storage SOP Class so that this IOD can be used in Network and Media Storage exchanges. The scope of the RT Structure Set IOD is radiotherapy patient-related structures which have been identified on devices such as CT scanners, virtual simulation workstations, or treatment planning systems. 4) A DICOM Plan Information Object for Radiotherapy. It specifies the semantic content of RT (Treatment) Plans. It is commonly abbreviated to the RT Plan IOD. It also includes the corresponding Storage SOP Class so that this IOD can be used in Network and Media Storage exchanges. The scope of the RT Plan IOD is geometric and dosimetric data specifying a course of external beam and/or brachytherapy treatment. This report includes a number of addenda to existing Parts of DICOM; therefore the reader should have a working understanding of the Standard. 1. Part 3 Addenda (Extension to the body, Annex A, B, C and D) 2. Part 4 Addenda (Extension to Annex B) 3. Part 6 Addenda (Extension to Section 6 and Annex A)

Best Sellers From Health Sector

GSO 2017:2023
 
Gulf Standard
Personal Care and Baby Wet Wipes
BH GSO 2017:2023
GSO 2017:2023 
Bahraini Standard
Personal Care and Baby Wet Wipes
BH GSO 2241:2023
GSO 2241:2023 
Bahraini Standard
Cosmetic Products - Body Cleaners
GSO 2241:2023
 
Gulf Standard
Cosmetic Products - Body Cleaners

Recently Published from Health Sector

GSO ISO 17069:2024
ISO 17069:2020 
Gulf Standard
Accessible design — Consideration and assistive products for accessible meeting
GSO ISO 11608-6:2024
ISO 11608-6:2022 
Gulf Standard
Needle-based injection systems for medical use — Requirements and test methods — Part 6: On-body delivery systems
GSO ISO 16256:2024
ISO 16256:2021 
Gulf Standard
Clinical laboratory testing and in vitro diagnostic test systems — Broth micro-dilution reference method for testing the in vitro activity of antimicrobial agents against yeast fungi involved in infectious diseases
GSO ISO 14708-3:2024
ISO 14708-3:2017 
Gulf Standard
Implants for surgery — Active implantable medical devices — Part 3: Implantable neurostimulators